Home > Articles  
PicoSearch
 

Library: Maxillofacial surgery
Article type: Original case report
DOI: 10.1102/1470-5206.2003.0007
Vol 3 pages 16-18

A magnetic fixation and orientation system for orthognathic surgery planning models

H. Popat and P. J. Sandler
Department of Orthodontics and Maxillofacial Surgery, Chesterfield and North Derbyshire Royal Hospital, Calow, UK

Corresponding address: P. J. Sandler, Consultant Orthodontist, Department of Orthodontics and Maxillofacial Surgery, Chesterfield and North Derbyshire Royal Hospital, Calow, Chesterfield, Derbyshire, S44 5BL, UK. Tel. +44 01246 552103
Email: JonSandler@AOL.com

Abstract

A useful method of handling orthognathic treatment models is described that utilises magnetic attachment of study models to an articulator, allowing rapid and reliable manipulation between pre- and post-operative positions of the maxilla and/or mandible. Both the orthodontic and surgical staff can easily study planned surgical movements.

Key words

Articulator, keyed spacer, magnets, orthognathic surgery, treatment planning

 Click here to view article

Click here for printer-optimised version

 

 

About this site